Sign in →

Test Code BFBL Bilirubin, Body Fluid

Reporting Name

Bilirubin, BF

Useful For

Evaluating peritoneal fluid or abdominal drain fluid as a screening test for bile leakage

 

May aid in the distinction between a transudative and an exudative pleural effusion

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Body Fluid


Ordering Guidance


For bilirubin testing on urine specimens, order BILUR / Bilirubin, Random, Urine. Testing will be changed to BILUR if this test is ordered on urine specimens.



Shipping Instructions


Ship specimen in amber vial to protect from light.



Necessary Information


1. Date and time of collection are required.

2. Specimen source is required.



Specimen Required


Supplies: Amber Frosted Tube, 5 mL (T915)

Preferred Source:

-Peritoneal fluid (peritoneal, abdominal, ascites, paracentesis)

-Pleural fluid (pleural, chest, thoracentesis)

-Drain fluid (drainage, Jackson Pratt [JP] drain)

-Pericardial fluid

Acceptable Source: Other body fluid, write in source name with source location (if appropriate)

Collection Container/Tube: Sterile container

Submission Container/Tube: Opaque, amber vial

Specimen Volume: 1 mL

Collection Instructions:

1. Centrifuge to remove any cellular material and transfer into an amber vial to protect from light.

2. Indicate the specimen source and source location on label.


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Body Fluid Frozen (preferred) 70 days LIGHT PROTECTED
  Refrigerated  14 days LIGHT PROTECTED

Day(s) Performed

Monday through Sunday

Test Classification

This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

82247

LOINC Code Information

Test ID Test Order Name Order LOINC Value
BFBL Bilirubin, BF 1974-5

 

Result ID Test Result Name Result LOINC Value
BRNBF Bilirubin (BF) 1974-5
FLD14 Fluid Type: 14725-6

Clinical Information

Peritoneal fluid:

Bilirubin is typically measured in peritoneal fluid of patients with suspected bile duct leak or gallbladder perforation as a screening test prior to imaging or cholescintigraphy. If the value is higher than that of serum and is greater than 6 mg/dL, and the ascitic fluid amylase is not elevated (indicating upper intestinal perforation), it can be assumed that the gallbladder has perforated into the peritoneum (choleperitoneum) or either bowel or biliary perforation has occurred.(1) Furthermore, biliary leakage after laparoscopic cholecystectomy is the most common post-operative complication.(2) While endoscopy is a beneficial first-line treatment for the management of bile leaks there often are logistical issues which hinder the procedure from being performed rapidly. Post-cholecystectomy patients generally have a drain in place (particularly a Jackson Pratt [JP] drain) and may undergo bilirubin testing on the drain fluid as an objective assessment of a bile leak. A body fluid/serum bilirubin ratio of greater than 5 in a JP drain fluid is highly sensitive and specific for bile leak.(3)

 

Pleural fluid:

Measurement of bilirubin in pleural fluid has been investigated to aid in the differentiation of transudative and exudative effusions in pursuit of more specific biomarkers than traditional light criteria measuring total protein and lactate dehydrogenase. Bilirubin values tend to be higher in exudates than in transudates, although there is some overlap between groups which limits the usefulness of its measure.(4)

 

Other fluids:

Determination of body fluid bilirubin concentration can aid in the distinction between a transudative and an exudative fluid or identify the presence of bile in other fluid compartments.

Cautions

Bilirubin is photosensitive. Failure to protect from light may cause decreased results.

 

In very rare cases, gammopathy, in particular type IgM (Waldenstrom macroglobulinemia), may cause unreliable results.

 

Cyanokit (Hydroxocobalamin) may cause false low results.

Report Available

Same day/1 to 2 days

Specimen Retention Time

1 week

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK
Anticoagulant or additive
Amniotic fluid
Breast milk
Saliva
Sputum
Cerebrospinal fluid
Bronchoalveolar lavage (BAL)
Bronchial washings
Colostomy
Ostomy
Gastric secretions
Nasal secretions
Urine
Feces
Vitreous fluid
Synovial fluid
Reject

Method Name

Photometric, Diazonium Salt

Secondary ID

606895