Test Code CRS Chromium, Serum
Reporting Name
Chromium, SUseful For
Screening for occupational exposure
Monitoring metallic prosthetic implant wear
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
SerumOrdering Guidance
The US Food and Drug Administration recommended test for monitoring chromium in patients with metal-on-metal implants is CRWB / Chromium, Blood.
Specimen Required
Patient Preparation: High concentrations of gadolinium and iodine are known to interfere with most metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.
Supplies: Metal Free Specimen Vial (T173)
Collection Container/Tube: Plain, royal blue-top Vacutainer plastic trace element blood collection tube
Submission Container/Tube: 7-mL Mayo metal-free, screw-capped, polypropylene vial
Specimen Volume: 0.5 mL
Collection Instructions:
1. Allow the specimen to clot for 30 minutes; then centrifuge the specimen to separate serum from the cellular fraction.
2. Remove the stopper. Carefully pour specimen into a Mayo metal-free, polypropylene vial, avoiding transfer of the cellular components of blood. Do not insert a pipet into the serum to accomplish transfer, and do not ream the specimen with a wooden stick to assist with serum transfer.
3. See Metals Analysis Specimen Collection and Transport for complete instructions.
Specimen Minimum Volume
0.3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | METAL FREE |
Ambient | 28 days | METAL FREE | |
Frozen | 28 days | METAL FREE |
Special Instructions
Day(s) Performed
Tuesday, Wednesday, Friday
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
82495
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
CRS | Chromium, S | 5622-6 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
8638 | Chromium, S | 5622-6 |
Clinical Information
Chromium (Cr) exists in valence states. Hexavalent chromium (Cr[+6]) and trivalent chromium (Cr[+3]) are the 2 most prevalent forms. Cr(+6) is used in industry to make chromium alloys including stainless steel, pigments, and electroplated coatings. Cr(+6), a known carcinogen, is immediately converted to Cr(+3) upon exposure to biological tissues. Cr(+3) is the only chromium species found in biological specimens.
Serum Cr concentrations are likely to be increased above the reference range in patients with metallic joint prosthesis. Prosthetic devices produced by DePuy Company, Dow Corning, Howmedica, LCS, PCA, Osteonics, Richards Company, Tricon, and Whiteside typically are made of chromium, cobalt, and molybdenum. This list of products is incomplete, and these products change occasionally; see prosthesis product information for each device for composition details.
Cautions
Specimens from unexposed individuals collected using metal-free collection procedures typically have chromium above 0.3 ng/mL. Chromium is present in our environment at 100-fold to 1000-fold higher concentration than found in biological tissues. Reports of increased serum chromium could be due to external contamination. Metal-free serum collection procedures must be followed, and centrifuged serum must be aliquoted into a Mayo Clinic Laboratories metal-free vial to avoid external contamination. Specimens collected using an anticoagulant are unacceptable; trace amounts of chromium are present in anticoagulants used in evacuated collection tubes.
Report Available
1 to 4 daysSpecimen Retention Time
7 daysReject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Method Name
Inductively Coupled Plasma-Mass Spectometry (DRC-ICP-MS)
Secondary ID
8638Royal Blue Top Trace Element Serum Tube: